The following shall be provided at the time of Development Works Approval:
- Electronic copy of the lighting design report and lighting design plans scaled to 1:500.
- The lighting design layout shall include all relevant topographic information, property boundaries, driveway crossovers, kerb line, footpath, landscaping, overhead power lines and any other elements relevant to lighting design constraints.
- Documentation in accordance with the relevant part(s) of AS/NZS1158 to show compliance.
- Lighting sub-category used in the design, e.g. V2, P4. These shall be recorded on each lighting plan.
- For category V roads: Luminance calculations from Perfectlite together with Isolux plots from AGI32, illustrating relevant contours for the lighting sub-category with illuminance and point illuminance values necessary to demonstrate compliance. Also include a 10 lux horizontal isolux line.Use of other software packages is acceptable, subject to Council approval
- For Category P roads: Illuminance diagrams from AGI32 illustrating relevant contours for the lighting sub-category with illuminance and point illuminance values necessary to demonstrate compliance. Use of other software packages is acceptable, subject to Council approval.
- Information shown in Table 1: Information Requirements for Category V Roads and Table 2: Information Requirements for Category P Roads.
Table 1: Information Requirements for Category V Roads
Parameter |
Symbol |
Notes |
Average carriageway luminance |
L |
Straight sections |
Overall uniformity |
Uo |
Straight sections |
Longitudinal uniformity |
UL |
Straight sections |
Threshold increment % |
TI |
Straight sections |
Surround (verge) illumination ratio |
Es |
Straight sections |
Perfectitle maximum spacing |
|
Straight sections |
Maximum spacing at bends |
|
Bends – Summarise reduced spacing values, showing the bend radius (m), reduction factor and reduced spacing (m). |
Point illuminance |
Eph |
Intersections, pedestrian crossings, pedestrian refuges and defined pedestrian crossing routes at signalised crossing |
Illuminance (horizontal) uniformity |
UE1 |
Intersections and pedestrian refuges only |
Vertical illuminance |
EPV |
Pedestrian crossing |
Table 2: Information Requirements for Category P Roads
Parameter |
Symbol |
Notes |
Average horizontal illuminance |
Eh |
|
Point horizontal illuminance |
Eph |
|
Illuminance (horizontal) uniformity |
UE2 |
|
Point vertical illuminance |
Epv |
|
Luminous intensity at Gamma 80 |
IG80 |
For maximum luminaire watts in the design |
Peak luminous intensity |
IPEAK |
For maximum luminaire watts in the design |
Perfectile maximum spacing |
|
Straight sections |
Definitions in this section
Design
Development works approval