Search
× Search
Menu
  1. Home
  2. General
  3. Infrastructure Development Processes
  4. Quality Assurance Information Requirements
    1. QA-1 Resource Consent Application Requirements
    2. QA-2 Works Undertaken By or For a Council
    3. QA-3 Development Works Approval
    4. QA-4 Survey Plan (s223) Approval
    5. QA-5 Final Sign Off (s224c) Application Requirements
    6. QA-6 As-Built Information
    7. QA-7 Bonds and Maintenance Fee
    8. QA-8 Building Consent Considerations
  5. Design Standards
    1. DS-1 General Provisions
    2. DS-2 Streetscape
    3. DS-3 Reserves
    4. DS-4 Transportation Network
    5. DS-5 Stormwater
    6. DS-6 Wastewater
    7. DS-7 Water Supply
    8. DS-8 Public Lighting
    9. DS-9 Network Utilities
    10. DS-10 Natural Hazards & Earthworks
    11. DS-11 Road Zone/Road Reserve Occupancy
    12. DS-12 Building Consent Considerations
  6. Standard Drawings
    1. SD-1 General Provisions
    2. Street design diagrams
    3. T100 Perspective Drawings
    4. T200 Streetscape
    5. T300 Reserves
    6. T400 Transport Network
    7. T500 Stormwater
    8. T600 Wastewater
      1. T601-Manhole - Standard
      2. T602-Manhole - Shallow
      3. T603-Manhole - Ladder and Steps
      4. T604-Manhole - Precast 1050mmØ Lid
      5. T605-Manhole - Entry Fixing
      6. T606-Manhole - Standard and Raised Access Detail
      7. T607-Manhole - Inclined Access Detail
      8. T608-Manhole - Internal Drop
      9. T609-Manhole - External Drop
      10. TT610-Manhole - PE Pipe Connections - Wall Adapter and Pre-Cast Manhole
      11. T611-Manhole - PE Pipe Connections - Stub Flange and In-Situ Base
      12. T612-Manhole - PE Pipe Connections - Electrofusion Coupler and In-Situ Base
      13. T613 Manhole - PE Pipe Connections - Puddle Flange and Pre-Cast Manhole
      14. T614-Manhole - Access Detail in Carriageway
      15. T620-Rodding Eye - Shallow < 2.5m
      16. T621-Rodding Eye - Deep > 2.5m
      17. T630-Property Connection - Standard
      18. T631-Property Connection - Depth > 2.5m
      19. T632-Property Connection - Within Property
      20. T633-Property Connection - Outside Property
      21. T634-Property Connection - Entry to Wastewater Main/Manhole
      22. T637-Lateral Connection - Single Connection to Manhole
      23. T638-Lateral Connection - Two or More Connections to Manhole
      24. T639-Lateral Connection - Single Connection to Main
      25. T640-Lateral Connection - Two Connections to Main
      26. T641-Lateral Connection - Two Adjacent Connections to Main
      27. T642-Lateral Connection - Rear Lot Connection
      28. T643-Mains Connection - Saddle Connection
      29. T651-Bedding and Backfill Details
      30. T652-Anti-Scour Block and Trenchstop
      31. T653-Buildings Near Public Mains
      32. T654-Close Proximity - Retaining Wall Restrictions
      33. T660-Pump Station - Typical Site Layout
      34. T661-Pump Station - Elevation Section
      35. T662-Pump Station - Plan Section
      36. T663-Pump Station - Pedestal Base Plate, Pedestal Mounting, Valve Chamber and Riser Connection
      37. T664-Pump Station - Deflector Plate, Ladder and Plinth
      38. T665-Pump Station - Valve Extension Spindle, Spindle Guide and Handwheel
      39. T666-Pump Station - Cover Slab
      40. T667-Pump Station - Frame
      41. T668-Pump Station - Chamber Lid
      42. T669-Pump Station - Chamber Lid Padlock and Handle
      43. T670-Pump Station - Rising Main Entry to Receiving Manhole
      44. T671-Pump Station - 25mm Water Service Connection
      45. T672-Pump Station - Electrical - Standard 2 Pump Stn Without Soft Starters (1 of 2)
      46. T673-Pump Station - Electrical - Standard 2 Pump Stn Without Soft Starters (2 of 2)
      47. T674-Pump Station - Electrical - Standard 2 Pump Stn SMC - 3 Soft Starters (1 of 2)
      48. T675-Pump Station - Electrical - Standard 2 Pump Stn SMC - 3 Soft Starters (2 of 2)
      49. T676-Pump Station - Electrical - Standard 2 Pump Stn IMS2 Soft Starters (1 of 2)
      50. T677-Pump Station - Electrical - Standard 2 Pump Stn IMS2 Soft Starters (2 of 2)
      51. T678-Pump Station - Electrical - Standard 2 Pump Stn ISMC - 3 Soft Starters (1 of 3)
      52. T679 Pump Station - Electrical - Standard 2 Pump Stn ISMC - 3 Soft Starters (2 of 3)
      53. T680-Pump Station - Electrical - Standard 2 Pump Stn ISMC - 3 Soft Starters (3 of 3)
      54. T681-Electrical - 2 Pump Stn Mincas SMC-3 Soft Starters (1 of 2)
      55. T682-Electrical - 2 Pump Stn Mincas SMC-3 Soft Starters (2 of 2)
      56. T683-Pump Station - Electrical Cabinet
    9. T700 Water Supply
      1. T700-Water Supply Pipe Hierarchy
      2. T701-Water Supply - Looped and Linked Principal Mains
      3. T705-Water Main - Location at Intersections
      4. T706-Watermain - Location at Cul de Sac
      5. T707-Water Main - Rider Main to Main Connection
      6. T708-Water Main - Flushing Point
      7. T709-Water Main - Branch Valves and Hydrant Combinations
      8. T710-Water Main - Support for Asbestos Cement Main
      9. T713-Hydrant Surround
      10. T714-Hydrant Box
      11. T715-Hydrant Surround Blocks
      12. T716-Valve Surround
      13. T717-Valve Box
      14. T718-Valve Surround 75mm Concrete
      15. T719-Valve Surround 100mm Concrete
      16. T720 Valve Surround Heavy Duty Concrete
      17. T721-Anchor block for Sluice Valves on Mains
      18. T722-Anchor Block for Flanged Fittings on Mains
      19. T723-Thrust Blocks
      20. T724-Hydrant and Valve Marker Post
      21. T727-Water Meter - Type 1 and 2 Point of Supply Location Installation
      22. T728-Water Meter - Type 3 and 4 Point of Supply Location Installation
      23. T729-Water Meter - Fire System Connection With Potable Supply Installation
      24. T730-Standard 20mm Manifold Connection
      25. T731-Standard 20mm Manifold Connections - Plan View
      26. T732-Multiple 20mm Installations
      27. T733-20mm Connection Requiring Double Check Valve
      28. T734-20mm Connection Requiring RPZ Installation
      29. T735-25mm, 40mm or 50mm Meter Installation With Double Check Valve
      30. T736-<50mm Meter Installation with RPZ
      31. T737-Property Connection - 50mm Combination Meter Installation with Double Check Valve
      32. T738-Combination Meter Installation with RPZ
      33. T739 >50mm Combination Meter Installation with RPZ & Bypass Option
      34. T740-Property Connection - Secure Connection
      35. T741-Manhole - Class A Loading
      36. T742-Chamber - Class A Loading
      37. T743-Manhole - Class B Loading
      38. T744-Chamber - Class B Loading
      39. T751-Bedding and Backfill Details
      40. T753-Buildings Near Public Mains
    10. T800 Public Lighting
    11. AB As-Built Drawings
  7. Approved Materials
  8. Construction Standards
    1. CS-1 General
    2. CS-2 Site Clearance
    3. CS-3 Earthworks
    4. CS-4 Excavation
    5. CS-5 Excavation in Trench
    6. CS-6 Fill
    7. CS-7 Bedding & Backfill
    8. CS-8 Subsoil Drainage for Earthworks & Roads
    9. CS-9 Pipework
    10. CS-10 Pipe Fittings
    11. CS-11 Manholes & Rodding Eyes
    12. CS-12 Sumps
    13. CS-13 Trenchless Technology
    14. CS-14 Road Ripping
    15. CS-15 Road Pavement Layers
    16. CS-16 Kerb & Channel
    17. CS-17 Concrete Work
    18. CS-18 Carriageway Surfacing
    19. CS-19 Roadmarking
    20. CS-20 Berm Features
    21. CS-21 Street Structures
    22. CS-22 Road Maintenance
    23. CS-23 Grassing & Turfing
    24. CS-24 Vegetation Planting & Gardens
    25. CS-25 Reinstatement
  9. Inspection & Testing Requirements
    1. IT-1 General Provision
    2. IT-2 Streetscape
    3. IT-3 Reserves
    4. IT-4 Transportation Network
    5. IT-5 Stormwater
    6. IT-6 Wastewater
    7. IT-7 Water Supply
    8. IT-8 Public Lighting
    9. IT-9 Network Utilities
Infrastructure Development Code

CS-6.1 Conditioning and Spreading of Fill

PreviousNext

Before fill is placed, the Contractor shall notify the Engineer that the fill foundation has been stripped, drained, (including subsoil drains) and prepared as per the Contract Drawings and documents and is ready for the Engineer’s inspection. 

Before compaction, fill materials shall be spread uniformly in horizontal layers and if necessary, be conditioned to an appropriate moisture content by aeration and drying or wetting (as the case may be), and/or by blending and mixing "wet" and "dry" materials. If soil is to be dried, the Contractor shall disc it and allow it to dry uniformly to its full depth. If the soil is to be wetted, this shall be done with sprinklers capable of ensuring uniform and controlled distribution of water in conjunction with blading and disking. In all cases the fill shall be mixed and conditioned thoroughly so that immediately before compaction the material type and its moisture content is reasonably uniform within one area and as close as practical of optimum moisture content. Before compaction the layers shall be less than 250mm loose thickness. All fragments within the loose layer shall be less than 100mm maximum dimension.

No new fill shall be placed over previously compacted material until the construction methodology to be utilised by the contractor has been reviewed and observed by the Engineer and Geo-Professional.  Once the construction methodology has been observed, the Engineer or the Geo-Professional shall confirm whether they are satisfied that continued placement of earth fill will ensure that all earthworks will meet the required compaction standards and testing methodology.

Effective drainage shall be maintained during filling operations to minimise any deterioration of material exposed in excavation areas and in the uppermost fill layers. 

Special care shall be taken to avoid hollows which could pond water. All fill surfaces shall be protected when rain is imminent to minimise erosion and protect the fill from strength loss of the fill due to an increase in moisture content.

Where fill is to be placed against sloping surfaces steeper than 1v:2h, the sloping surface shall be excavated ("benched") such that horizontal benches no greater than 1.0m height intervals are formed.

Filling shall be carried out so that no area of fill is ever more than 0.5m higher than any other adjacent area of filling unless approved by the Engineer.

In order to ensure adequate compaction of the materials forming the final fill surface profile, all fill batter faces shall be overfilled as necessary and carefully trimmed back to the required design profile.


Definitions in this section

Contractor

Design

Engineer

Geo-professional

Tauranga City Council, Private Bag 12022, Tauranga, 3143, New Zealand  |  Terms of use

Back To Top